查询RAID卡固件版本的方法有如下两种:
进入如图3-4所示界面。
显示当前存在的RAID卡列表,如图3-5所示。
进入如图3-6所示主界面。
进入“Main Menu”页面,如图3-7所示。
显示RAID卡基本信息。界面中的“Firmware Version”即为RAID卡的固件版本,如图3-8所示。
./storcli64_arm /c0 show
[root@localhost ~]# ./storcli64_arm /c0 show
Generating detailed summary of the adapter, it may take a while to complete.
Controller = 0
Status = Success
Description = None
Product Name = SAS3108
Serial Number =
SAS Address = 5101b5442bcc7000
PCI Address = 00:49:00:00
System Time = 06/27/2019 05:04:22
Mfg. Date = 00/00/00
Controller Time = 06/27/2019 09:04:20
FW Package Build = 24.16.0-0093
BIOS Version = 6.32.02.0_4.17.08.00_0x06150500FW Version = 4.660.00-8140Driver Name = megaraid_sas
Driver Version = 07.709.08.00
Current Personality = RAID-Mode
Vendor Id = 0x1000
Device Id = 0x5D
SubVendor Id = 0x19E5
SubDevice Id = 0xD20F
Host Interface = PCI-E
Device Interface = SAS-12G
Bus Number = 73
Device Number = 0
Function Number = 0
Drive Groups = 1
TOPOLOGY :
========
-----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
-----------------------------------------------------------------------------
0 - - - - RAID0 Optl N 744.125 GB dflt N N none N N
0 0 - - - RAID0 Optl N 744.125 GB dflt N N none N N
0 0 0 53:2 57 DRIVE Onln N 744.125 GB dflt N N none - N
-----------------------------------------------------------------------------
...